产品介绍:A2G-100是一款为空调系统以及通风行业专门研发,用于控制气流及差压的多功能PID控制器。PID控制器能使持续的压力或者气流控制电子换相(EC)风扇、多风量系统(VAV系统)或者排风扇。气流控制是通过在启动菜单中输入制造商的风机常数KFAN,或者使用A2G-FM的测量探针来实现。0...10 V或者4...20 mA的输出信号作为控制信号被直接连接至EC通风设备或者变频器(FI)上。A2G-100的两行LCD显示可同时显示输出信号以及测量值。用户可以通过仪表的跳线来设置0...10 V或者4...20 mA的电子模拟输出信号。同时该控制器支持自动调零功能。应用用于电子换相(EC)风扇的持续控制或直接连接至变频器(FI)气流差压产品特性可通过菜单设置所有参数两行LCD显示实现良好的可读性简单快速的安装和调试无需维护**操作压力25 kPa
Series TDC Remote Flow Controller coupled with a thermal dispersion flow switch (Series TDS) provides a complete system for leak detection, signaling high or low flow conditions, low flow cutoff, and pump or valve actuation. Controller features adjustable time delay for dampening of relay chatter, selectable NO or NC operation, and LED indication of sensor, relay, and power status. Model TDC1 accepts single switch input and single relay output. Model TDC2 accepts three switch inputs and two relay outputs.
The Series APM has a unique, rugged, NEMA 4X front panel design that makes it nearly impenetrable in typical applications. The weatherproof, UV resistant, large, dual line display allows for more information making it easier to read and even simpler to program. The intensity of the display can be adjusted allowing this meter to be utilized in dark rooms as well as outdoors, due to its sunlight readable display. It features up to eight visual alarm set points to trigger certain events and three function keys which can be programmed to provide direct menu access. With up to four relays available, the APM features latching, nonlatching, sampling, pump alteration control, and a fail-safe action. Offering programmable delay time, this meter prevents recognition of false maximum or minimum reading which may be caused by the start-up or unusual process events. The APM provides three security passwords that restrict modification of programmed settings. This unit has the ability to obtain non-linear input signals and linearize them with simple to use math functions such as square-root extractor, weirs and flumes exponential linearizer, horizontal round tank linearizer or general purpose 32-point linearizer. Unit accepts 0 to 20 mA, 4 to 20 mA, 0 to 5V, or ±10V inputs and requires 85-265 VAC or 12/24 VDC power supply. Choose from RS-232, RS-422/485 serial communication options or any available expansion modules, accessories, and enclosures.The APM is a 1/8 DIN digital panel meter specifically designed for displaying flow rate and total from a flow meter with an analog output such as 4 to 20 mA or 0 to 10V. The APM is particularly well-suited for flow applications and can be programmed for a wide variety of display configurations. The upper line can display either flow rate, total or grand total, and the lower line can display either flow rate, total, grand total, or engineering units. It is possible to display flow rate and total at the same time, a very unique feature on a 1/8 DIN digital panel meters.Note: Shallow depth meters will not work with this Series.
The Series MPM has a unique, rugged, NEMA 4X front panel design that makes it nearly impenetrable in typical applications. The weatherproof, UV resistant, large, dual line display allows for more information, making it easier to read and simpler to program. The intensity of the display can be adjusted allowing this meter to be utilized in dark rooms as well as outdoors, due to its sunlight readable display. It features up to eight visual alarm set points to trigger certain events and three function keys, which can be programmed to provide direct menu access. With up to four relays available, the MPM features latching, non-latching, sampling, pump alteration control, and a fail-safe action. Offering programmable delay time, this meter prevents recognition of false maximum or minimum reading which may be caused by the start-up or unusual process events. The MPM provides three security passwords that restrict modification of programmed settings. The MPM has the ability to obtain non-linear input signals and linearize them with simple to use math functions such as square-root extractor, weirs and flumes exponential linearizer, horizontal round tank linearizer or general purpose 32-point linearizer. Unit accepts 0 to 20 mA, 4 to 20 mA, 0 to 5V, or ±10V inputs and requires 85 to 265 VAC or 12/24 VDC power supply. Choose from RS-232, RS-422/485 serial communication options or any available expansion modules, accessories and enclosures.Note: Shallow depth meters will not work with this Series.
The Series PPM has a unique, rugged, NEMA 4X front panel design that makes it nearly impenetrable in typical applications. The weatherproof, UV resistant, large, dual line display allows for more information, making it easier to read and simpler to program. The intensity of the display can be adjusted allowing this meter to be utilized in dark rooms as well as outdoors, due to its sunlight readable display. It features up to eight visual alarm set points to trigger certain events and three function keys which can be programmed to provide direct menu access. With up to four relays available, the PPM features latching, non-latching, sampling, pump alteration control, and a fail-safe action. Offering programmable delay time, this meter prevents recognition of false maximum or minimum reading which may be caused by the start-up or unusual process events. The PPM provides three security passwords that restrict modification of programmed settings. This unit has the ability to obtain non-linear input signals and linearize them with a general purpose 32-point linearizer. Choose from RS-232, RS-422/485 serial communication options or any available expansion modules, accessories, and enclosures.The PPM displays flow rate and total simultaneously, with a programmable relay and 4 to 20 mA option for flow rate or flow total. The PPM is a 1/8 DIN digital panel meter specifically designed for displaying flow rate and total from a pulsed input provided by open collector, NPN, PNP, TTL, switch contact, sine wave, or square wave.Note: Shallow depth meters will not work with this Series.
产品介绍:SITRANS P500是为了满足**的测量精度、坚固、用户友好的期望而开发的,它完全地融入到SITRANS P家族之中。借助SITRANS P500,你可以得到**水平的压力测量。它在保证≤ 0.03 %测量精度的同时还提供了出色的静压和温度影响量。因此,它能保证在量程比高达10:1之内≤ 0.14 %总性能。这些特性意味着一个测量单元可以用于不同量程的测量,库存成本大大减少的同时却不失测量结果的质量。由于传感器的长期稳定性性能确保了校验间隔时间的延长,结果能帮助您减少维护成本,这也使得您可以长期地信任测量结果。创新的传感器设计使得无需连接远传系统即可在高至125°C (257 °F)的过程温度下直接连接使用。借助用于设备设置的改进的3个就地操作按键,SITRANS P500的许多诊断功能无需软件即可便利地使用。甚至曲线显示和趋势图也可呈现在显示器以实现用户友好的过程监控。详情精度≤ 0,03 %(量程比高至10)长期稳定性0.05 % / 5年量程0 - 1,25 mbar 到 0 - 1250 mbar特点■ **的测量精度■ 极短的阶跃响应■ 出色的长期稳定性■ 优化了的操作员输入:可以通过一个纯文本、背光显示和3按键而高度用户友好地进行就地设置。变送器亦可通过控制系统使用 HART协议来方便地配置和操作。■ 借助新的快速启动向导和改进的EDD通过HART进行快速配置■ 诸如8个*小/**指示器显示过程值和事件时间的扩展自诊断功能■ 无需远传密封的高至125 °C (257 °F)的直接过程测量温度■ 背光、图形显示■ 由于长度只有86 mm (3.4“)的容室法兰而节省了安装空间
产品介绍:SITRANS P DSIII系列包含用于测量仪表压力、**压力、差压、流量和物位的数字压力变送器。甚至是标准型设备也提供广泛的、高可靠度的诊断和仿真功能。在SIL2回路中使用的适合度已经经过外部测试机构的鉴定。借助PROFIBUS变送器,新的PROFISAFE技术确保了从控制系统到变送器的一致安全。详情精度≤ 0.075 %长期稳定性≤ 0.25 % / 60 months量程0 - 10 mbar (0 - 0,4 inchH2O) 至0 - 400 bar (0 - 5800 psi)特点■ 扩展诊断和仿真功能■ 依据IEC 61508 /IEC 61511,适合于SIL2应用中的安装。PROFIsafe型号下,它确保至控制系统级别的**通讯安全■ 大量的鉴定和认可,例如ATEX EEx ia、EEx ib、防尘、FM、CSA ■ 可选使用一个仿真功能用于回路检查■ 开放了许多不同的总线通讯选项:HART、PROFIBUS PA、PROFIsafe或FF